EU Battery Info Page · Article 13(6) · Non-DPP
FC12-100
Industrial Lead-Acid Battery · 12V / 100Ah / 1.2kWh
Exemption Declaration
This battery is ≤ 2 kWh and therefore exempt from Article 77(1) DPP obligation under EU Battery Regulation (EU) 2023/1542. It is not registered in the Central Registry passport index. This page fulfills Article 13(6) information requirements only. Labeling obligations under Article 13(2)–(5) remain fully applicable.
Identity & Traceability
| Category | Industrial Battery (≤2kWh) |
| Manufacturer | MCA Battery Manufacture Co.,Ltd |
| Production Site | Duichuan Industrial Zone, Yanghe Town, Gaoming, Foshan, Guangdong, China |
| Date of Mfg. | 2026-12-01 |
| Batch No. | 2026C12-004512 |
| Dimension | 331x174x219(mm) |
| Gross Weight | 29.2 kg |
| Info URL | http://www.mcabattery.com/DPP/FC12-100-12V100AH/1.2KWH3 |
Technical Parameters
| Chemistry | PbA-VRLA-AGM |
| Rated Voltage | 12 V |
| Capacity | 100 Ah |
| Energy | 1.2 kWh |
| Float Voltage | 13.5~13.8 V |
| Design Life | 10 yrs (standby) |
| Safety | Pressure Relief, Leak-proof |
Labeling & Compliance (Art.13)
| Separate Collection | Crossed-out wheelie bin |
| Chemical Marking | Pb (Lead ≥ 0.004%) |
| CE Marking | CE |
| Capacity Threshold | ≤2kWh · Art.77 Exempt |
Scope Note
This product is a standalone industrial battery. Primary end-of-life obligation falls under Battery Regulation (separate collection). WEEE registration applies only when supplied with or embedded in electrical equipment.
Materials & Circularity
| Key Material | Lead (~60% by wt) |
| Recycled Lead | 88.0% (voluntary) |
| Voluntary disclosure · Not a compliance claim | MBAL-2026-00456 |
Safety Warning
• Electrolyte: Sulfuric acid (H₂SO₄) — rinse immediately on skin contact
• Ventilation required during charging (hydrogen gas release)
• Weight: ≥20kg — use mechanical aid for repeated lifting
• PPE: Acid-resistant gloves + eye protection + apron
End-of-Life Handling
• Contains lead-acid — do NOT dispose of in household waste
• Return whole battery to authorized battery collection point (not mixed WEEE stream)
• Battery EPR scheme ensures free take-back via registered recyclers
• Do NOT dismantle or incinerate
• Lead components 100% recyclable via authorized smelters
• Find nearest recycler → EU Battery Collection Network
Carbon & Due Diligence
| Carbon Footprint | Not disclosed (Art.77 exempt) |
| Due Diligence | OECD-aligned policy applied · see DoC Annex |
Non-DPP notice: This page does NOT contain full DPP fields, evidence chains, recycler restricted layer, or authority full-access layer. For DPP-required batteries (>2kWh), see separate passport page.
Data scope: Article 13(6) only — identity, labeling, basic safety, end-of-life guidance.
© MCA Battery Manufacture Co.,Ltd